Specialty Structure Contractor Practice Exam Florida (Quiz)
Work through 7 specialty structure contractor practice exam Florida questions on screen enclosures, roofovers and aluminum rules. Start free.
Taking a specialty structure contractor practice exam Florida candidates can use to test real code lookups is the smartest way to prepare for the Certified Specialty Structure Contractor (SCC) license. In Florida, this statewide certification covers screen and pool enclosures, sunrooms, manufactured home roofovers, hurricane protection devices, aluminum fences, siding, soffit, fascia, and gutters. Candidates must pass both the 120 question Business and Finance exam and the 80 question Specialty Structure Trade Knowledge exam at Pearson VUE with at least 70 percent. Every figure below was checked against Florida Statutes Chapter 489, Chapter 61G4-15, F.A.C., and Rule 61G4-16.001, F.A.C. in October 2026. Answer the seven original study practice questions below (not copied from the confidential state exam).
What Does the Florida Specialty Structure Contractor Exam Cover?
The Florida specialty structure contractor exam is an open book, computer based test consisting of 80 equally weighted multiple choice questions with a five hour time limit, requiring 56 correct answers (70 percent) to pass. Under Rule 61G4-16.001, the Construction Industry Licensing Board distributes the exam across eight content areas:
- Wall sections: 15 percent (about 12 questions)
- Roof sections: 15 percent (about 12 questions)
- Windows: 15 percent (about 12 questions)
- Post and beam structures: 15 percent (about 12 questions)
- Roofovers: 15 percent (about 12 questions)
- Siding, soffit, fascias, gutters, and downspouts: 10 percent (about 8 questions)
- Foundations: 7.5 percent (about 6 questions)
- Insulation: 7.5 percent (about 6 questions)
Read the complete licensing overview on our Florida specialty structure contractor license hub.

What Are the Scope Limits for a Florida Specialty Structure Contractor License?
Before you sit for the exam, you must know the exact legal boundaries of a Florida specialty structure contractor license under Board Rule 61G4-15.015, because several questions test where aluminum and enclosure work stops and general or building contracting begins.
- The license covers work in aluminum, metal, canvas, vinyl, and fiberglass screening, doors and windows, hurricane protection devices, screened porches, pool enclosures, sunrooms, siding, soffit, fascia, gutters, and guardrails or handrails.
- Single story aluminum utility storage structures are limited to a maximum of 720 square feet.
- Window and door installation is limited to Group R (residential) occupancy buildings up to three stories or 30 feet in height, whereas windstorm protective devices (except impact resistant glazing) have no height limit.
- Concrete and masonry are permitted only for foundations, slabs, and block kneewalls incidental to the aluminum work; the contractor may never alter the structural integrity of a building (such as roof trusses, lintels, or load bearing walls).
Specialty Structure Contractor Practice Exam Florida: Questions 1 and 2 (Scope)
Use these specialty structure contractor practice exam Florida questions to test statutory scope limits and concrete work.
- Question 1 (Scope): Under CILB rules for a Certified Specialty Structure Contractor, which project is within the SCC license scope? A) 6th floor office windows. B) Single story aluminum storage structure up to 720 square feet, or windows on a Group R building up to three stories (30 feet) high. C) Load bearing lintels and trusses. D) Impact curtain walls on a 12 story hotel.
- Answer 1: B. Rule 61G4-15.015 allows single story aluminum structures up to 720 square feet and Group R windows up to three stories or 30 feet, without structural changes.
- Question 2 (Concrete): What concrete work may a Specialty Structure Contractor perform when building a sunroom? A) Post tensioned slabs. B) Foundations, slabs, and block kneewalls incidental to the aluminum work. C) Retaining walls over 8 feet. D) None.
- Answer 2: B. Incidental foundations, slabs, and kneewalls are permitted.
Screen Enclosure Contractor Exam Prep: Questions 3 and 4 (FBC & Aluminum)
Effective screen enclosure contractor exam prep focuses on FBC Chapter 20 (Aluminum) and the Aluminum Design Manual.
- Question 3 (Wind Loads): Under FBC Chapter 20 and the Aluminum manual, how are screen enclosures engineered for wind loads? A) Exempt. B) Frames, posts, beams, and cables use porous screen wind pressure coefficients and span tables by wind speed and exposure. C) Zero load. D) Steel I beams.
- Answer 3: B. Screen enclosures are engineered under FBC Chapter 20 and the Aluminum manual using wind span tables.
- Question 4 (Metals): Under 2023 FBC Section 2002.1 and the Aluminum Design Manual, when aluminum contacts concrete, masonry, or treated wood, what is required? A) Uncoated steel screws. B) An approved alkali resistant coating, bituminous paint, or nonabsorptive barrier to prevent corrosion. C) Welding to rebar. D) A 2 inch gap.
- Answer 4: B. FBC Section 2002.1 and the Aluminum Design Manual require an approved coating or barrier against concrete or treated wood.
Florida Specialty Contractor Exam Prep: Questions 5 and 6 (Footings & Roofovers)
This Florida specialty contractor exam prep section covers footing math (7.5 percent of the exam) and manufactured home roofovers (15 percent).
- Question 5 (Slab Math): You are pouring a 4 inch patio slab measuring 30 feet by 15 feet, plus an edge beam requiring 1.5 cubic yards. Including 5 percent waste, how many cubic yards of concrete must you order? A) 5.56. B) 7.06. C) 7.41. D) 16.50.
- Answer 5: C. Slab volume is 150 cubic feet (5.56 cubic yards). Add 1.50 cubic yards (7.06), times 1.05 waste = 7.41 cubic yards.
- Question 6 (Roofovers): When installing an insulated aluminum roofover on a manufactured home, which two exam content areas account for 22.5 percent of the test? A) Medical gas and boilers. B) Roofovers (15 percent) and insulation (7.5 percent). C) Pile driving and steel. D) Three phase motors.
- Answer 6: B. Roofovers carry 15 percent weight and insulation carries 7.5 percent weight under Rule 61G4-16.001.
Question 7 and How to Score Your Specialty Structure Practice Run
Portable ladder and jobsite safety questions from OSHA 29 CFR 1926 appear regularly on the 80 question exam.
- Question 7 (OSHA Portable Ladder Safety): Under OSHA 29 CFR 1926.1053(b)(1), when portable extension ladders are used for access to an upper landing surface (such as a patio roof header), the ladder side rails must extend at least how many feet above the upper landing surface? A) 1 foot. B) 2 feet. C) 3 feet. D) 5 feet.
- Answer 7: C. Portable ladder side rails must extend at least 3 feet (0.9 m) above the upper landing surface, and the horizontal distance from the top support to the foot of the ladder must be one quarter of the working length (4:1 angle).
- Scoring Your Run: Scoring at least 5 out of 7 (71 percent) aligns with the 70 percent passing grade (56 out of 80 questions) required on exam day.

Frequently Asked Questions (FAQ)
How many questions are on the Florida Specialty Structure Contractor exam?
The Florida Specialty Structure Trade Knowledge exam has 80 equally weighted multiple choice questions with a five hour time limit at Pearson VUE. It is an open book test requiring a score of at least 70 percent (56 correct answers). Candidates also pass the 120 question Business and Finance exam.
Is a Specialty Structure Contractor license mandatory in Florida?
At the state level, Florida Statutes establish certified specialty contractor categories by board rule as voluntary statewide licenses that allow you to pull permits across all 67 Florida counties without taking separate local county competency exams. Always check local building department requirements where you work.
Can a Specialty Structure Contractor install windows and hurricane shutters?
Yes, within specific limits. Under Board Rule 61G4-15.015, a Specialty Structure Contractor may install windstorm protective devices (except impact resistant glazing) without a height limit, and may install windows and doors on Group R (residential) occupancy buildings up to three stories or 30 feet in height.
How can I access free specialty structure practice questions online?
Start with the seven worked questions on this page, then sign up for a free student account on our Free Course page. Registration is 100 percent free with no credit card required and unlocks the License Fix Student Portal and foundational Business and Finance lessons.
Start Your Specialty Structure Exam Prep for Free Today
Working through a specialty structure contractor practice exam Florida quiz gives you a clear benchmark, but passing both the 80 question Specialty Structure Trade Knowledge exam and the 120 question Business and Finance exam takes structured practice. Create your free student account right now on our Free Intro to Business and Finance Course page with no credit card required. Inside your free account, you get immediate access to the License Fix Student Portal on your phone or computer, Business and Finance video training, and extra free contractor practice test questions. When you are ready for full trade preparation, enroll in our self paced Florida Specialty Structure Trade Exam Preparation Course.

About Pascual, Contractor Licensing Instructor
Contractor Licensing Instructor
Pascual is a Florida contractor licensing exam prep specialist, with a focus on the Business & Finance and General Contractor exams. He has helped numerous candidates prepare for and pass their state exams, combining technical knowledge of Florida's regulations with practical study strategies. His approach is straightforward and grounded in real experience with the exam format, helping future contractors understand not just the content, but also how to avoid the most common mistakes that trip up candidates.
More from Pascual, Contractor Licensing Instructor